Sfondo Header
L'angolo del dottorino
Search the site... Advanced search
✖

Smartwatch reports an irregular rhythm or atrial fibrillation:
what to do

A notification of an irregular rhythm or possible atrial fibrillation should not be ignored, but it does not automatically amount to a diagnosis. Smartwatches can recognize patterns compatible with some arrhythmias, and some models can record a single-lead ECG, but algorithms, sensors, and recording conditions have limitations.
If the notification appears in a person who feels well, it is useful to save it and arrange appropriate assessment. If instead there is chest pain, significant breathing difficulty, fainting, sudden neurological deficits, or rapid worsening, urgent care should be sought regardless of what the watch displays.

After a notification, it is useful to:


Atrial fibrillation is one of the arrhythmias that wearable devices most frequently attempt to identify. A smartwatch can be a useful detection or documentation tool, but it does not replace clinical assessment.

An irregular rhythm notification and a smartwatch ECG are not the same thing

Many monitoring features use photoplethysmography (PPG): optical sensors analyze changes in blood flow at the wrist and estimate whether the intervals between beats are regular. This technology can generate a notification when it recognizes a pattern compatible with atrial fibrillation, but it does not directly record the heart's electrical activity.
The ECG function, when available, instead uses electrodes integrated into the device to obtain an electrical tracing, generally a single-lead recording. A readable ECG recorded during the episode therefore provides more direct diagnostic information than a simple optical notification.

A smartwatch ECG also has limitations: it has fewer leads than a clinical 12-lead ECG, and the algorithm may classify some tracings as inconclusive or interpret them incorrectly. The EHRA practical guide therefore recommends clinical review of recordings before important treatment decisions are made.

How reliable is a smartwatch and why can it be wrong?

Studies show that several devices can achieve good accuracy in recognizing atrial fibrillation when signal quality is adequate. Accuracy observed in a study, however, does not mean that every notification received by an individual person is correct.
Movement, poor skin contact, tremor, premature beats, and other arrhythmias can interfere with analysis. In addition, the predictive value of a notification depends on the probability that the person actually has atrial fibrillation: in low-risk populations, even an accurate algorithm can generate alerts that are not subsequently confirmed.

The opposite problem is equally important: no notification does not mean no arrhythmia. Apple, for example, specifies that the irregular rhythm feature does not continuously look for atrial fibrillation and therefore cannot identify every episode. People with significant symptoms should not be reassured solely because the watch has not reported anything.

What to do in practical terms after a possible atrial fibrillation alert

If the person is stable, the first useful step is to preserve the information. If the device has an ECG function, it is reasonable to make a recording according to the manufacturer's instructions and save the full tracing with date and time. If symptoms stop before the recording can be made, their duration and characteristics should still be noted.
A new or repeated alert deserves assessment, especially in people whose age or clinical conditions increase the likelihood of atrial fibrillation. The doctor can decide whether the tracing is sufficient or whether a 12-lead ECG, Holter monitor, or longer monitoring is needed.

An anticoagulant should not be started, extra doses of antiarrhythmic drugs should not be taken, and treatments should not be stopped on the basis of the notification alone. Decisions about stroke prevention and heart-rate or rhythm control require confirmation of the condition and individual assessment.

When the symptoms, not the smartwatch, are the priority

A wearable device is not a tool for ruling out an emergency. In the presence of chest pain or pressure, significant shortness of breath, fainting or near-fainting, confusion, sudden weakness on one side of the body, difficulty speaking, or other sudden neurological deficits, emergency services should be activated without waiting for the device to record or classify the rhythm.
Similarly, a smartwatch does not diagnose a heart attack through its irregular-rhythm feature. A single-lead wrist ECG should not be used by the patient to rule out an acute coronary syndrome.

If, on the other hand, there are no warning symptoms and the notification is isolated, there is no need to turn the device into a continuous checking tool. Repeating dozens of measurements can generate artifacts and anxiety without adding useful information. One good-quality recording and appropriate assessment are generally more informative.

Frequently asked questions about smartwatches and irregular rhythm

Does a notification mean I definitely have atrial fibrillation?
No. It is a signal that needs to be verified; false positives and other arrhythmias are possible.
If the smartwatch does not report anything, can I rule it out?
No. Monitoring is not necessarily continuous, and episodes may not be detected.
Is it useful to save the smartwatch ECG?
Yes. A tracing obtained during symptoms can be very useful, especially if it is kept in the original format or as a PDF with date and time.

Should I start an anticoagulant after a notification?
No. This type of treatment requires diagnostic confirmation and clinical assessment of risk.
When should urgent help be sought?
When chest pain, significant breathing difficulty, fainting or near-fainting, sudden neurological deficits, or rapid worsening occur.

References
  1. Svennberg E, Tjong F, Goette A, et al. How to use digital devices to detect and manage arrhythmias: an EHRA practical guide. Europace. 2022;24(6):979-1005. doi:10.1093/europace/euac038.
  2. Van Gelder IC, Rienstra M, Bunting KV, et al. 2024 ESC Guidelines for the management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS). European Heart Journal. 2024.
  3. Joglar JA, Chung MK, Armbruster AL, et al. 2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation. Circulation. 2024;149:e1-e156. doi:10.1161/CIR.0000000000001193.
  4. Perez MV, Mahaffey KW, Hedlin H, et al. Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation. New England Journal of Medicine. 2019;381:1909-1917. doi:10.1056/NEJMoa1901183.
  5. Lubitz SA, Faranesh AZ, Atlas SJ, et al. Rationale and design of a large population study to validate software for the assessment of atrial fibrillation from data acquired by a consumer tracker or smartwatch: The Fitbit Heart Study. American Heart Journal. 2021;238:16-26. doi:10.1016/j.ahj.2021.04.003.
  6. Lubitz SA, Faranesh AZ, Selvaggi C, et al. Detection of Atrial Fibrillation in a Large Population Using Wearable Devices: The Fitbit Heart Study. Circulation. 2022;146(19):1415-1424. doi:10.1161/CIRCULATIONAHA.122.060291.
  7. Wasserlauf J, You C, Patel R, et al. Smartwatch Performance for the Detection and Quantification of Atrial Fibrillation. Circulation: Arrhythmia and Electrophysiology. 2019;12(6):e006834. doi:10.1161/CIRCEP.118.006834.
  8. Vetta G, Magnocavallo M, Parlavecchio A, et al. Diagnostic accuracy of smartwatch in detecting atrial fibrillation: a systematic review and meta-analysis. European Heart Journal. 2023;44(Suppl 2).
  9. European Society of Cardiology. 2024 ESC Guidelines for the management of atrial fibrillation. ESC. 2024.
  10. Apple Inc. Heart health notifications on Apple Watch. Apple Support. Updated September 30, 2026.
  11. American Heart Association. What is Atrial Fibrillation?. American Heart Association.

Informational notice: the information contained on this page is provided solely for informational and educational purposes and does not replace the advice, diagnosis or treatment provided by a physician. If needed, always consult a qualified healthcare professional.

Artificial intelligence transparency: this page was created with the support of artificial intelligence tools, used to assist in the production and processing of its content.