Sfondo Header
L'angolo del dottorino
Search the site... Advanced search
✖

Implantable defibrillator:
what you can do and what to avoid

The implantable cardioverter-defibrillator (ICD) continuously monitors heart rhythm and can intervene when it detects potentially dangerous ventricular tachycardia or ventricular fibrillation. Many devices first attempt antitachycardia pacing and, if necessary, can deliver a shock.
Having an ICD does not mean living while waiting for a shock. After healing, many people return to normal activities. However, it is important to know what to do if a shock occurs, avoid close contact with powerful magnets, and attend device follow-up appointments.

The most important practical rules are:


The ICD is used mainly to prevent sudden death in people at risk of ventricular tachycardia or ventricular fibrillation. In some patients it is implanted after a cardiac arrest; in others it is used for primary prevention when risk is high even without a previous arrest.

What to do if the ICD delivers a shock

A shock may feel like a very strong, sudden blow to the chest. If you feel severe dizziness or as though you may faint before therapy is delivered, it is prudent to sit or lie down to avoid injury if consciousness is lost.
If you receive a single shock and feel well immediately afterward, specialist centers consistently recommend contacting the team that follows your ICD promptly. The device stores information about the rhythm that triggered therapy, and it may be possible to send these data through remote monitoring.

If, on the other hand, you experience chest pain, severe shortness of breath, marked weakness, confusion, persistent palpitations, or other significant symptoms after a shock, urgent medical attention is required. The same applies in the case of two or more shocks close together: they may indicate repeated arrhythmic episodes or, less commonly, inappropriate therapies and require immediate assessment.
A person touching the patient during the shock is not subjected to dangerous defibrillation: the shock is delivered through the implanted system.

Phone, smartwatch, magnets, and electrical devices

Common household electrical appliances that are working properly can generally be used. The main concern is powerful magnets, because a magnetic field close to the ICD can temporarily activate magnet mode and suspend antitachycardia therapies.
The FDA and American Heart Association recommend keeping mobile phones, smartwatches, earbuds, and other devices containing magnets at least about 15 centimeters from the generator. It is therefore not advisable to place a smartphone on the chest or carry it in a pocket directly over the ICD.

High-power industrial equipment, arc welders, and strong electromagnetic fields require specific guidance. People who routinely work with this equipment should discuss it with their ICD center rather than applying generic rules.

Travel, security screening, sports, and everyday activities

Traveling by car, train, or airplane does not damage the ICD. At security checkpoints, declare the device and show the identification card. Passing normally through a metal detector should not cause problems, but do not stop or lean against the gate; if a handheld wand is used, ask that it not be held over the generator longer than necessary.
The ability to drive is a different issue from the device's compatibility with a car: restrictions depend on the reason for implantation, any arrhythmias or shocks, and applicable regulations. They should therefore be specified by the cardiologist for the individual case.

Many forms of physical activity are possible after healing. The main limitation is determined by the heart disease that led to implantation and the risk that an arrhythmia could cause loss of consciousness. Contact sports may also strike the generator or leads and should be assessed specifically.

MRI, procedures, and device follow-up

Before any medical procedure, report the presence of the ICD. MRI is not automatically prohibited: many modern systems are MRI-conditional and, at experienced centers, protocols may also exist for some other systems. However, the generator, leads, and specific conditions must be checked before the examination.
Electrosurgery, radiotherapy, and other procedures may also require temporary programming or precautions. Do not place a magnet on the ICD on your own: its effect may disable antitachycardia therapies while the magnet remains in place.

Periodic follow-up checks the battery, leads, recorded arrhythmias, and delivered therapies. Remote monitoring can transmit data without an in-person visit every time, but it does not replace all clinical evaluations. If the device emits an unfamiliar audible alert or vibration, contact the center.

Frequently asked questions about an implantable defibrillator

What should I do after a shock?
If there is only one shock and you feel well, contact the ICD center promptly. If you feel unwell or the shocks are repeated, urgent medical attention is required.
Is someone who touches me during the shock at risk?
No. The shock is delivered through the implanted system and does not pose a significant danger to someone nearby.
Can I use a mobile phone?
Yes, keeping it at least about 15 cm from the generator and not carrying it in the pocket over the ICD.

Can I exercise?
Often yes, but the choice depends mainly on the heart disease, arrhythmic risk, and type of activity.
Can the ICD deliver inappropriate shocks?
Yes, although they are less common with modern programming. This is why every shock should be evaluated by the center.

References
  1. Zeppenfeld K, Tfelt-Hansen J, de Riva M, et al. 2022 ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death. European Heart Journal. 2022;43(40):3997-4126. doi:10.1093/eurheartj/ehac262.
  2. Al-Khatib SM, Stevenson WG, Ackerman MJ, et al. 2017 AHA/ACC/HRS Guideline for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death. Circulation. 2018;138(13):e272-e391. doi:10.1161/CIR.0000000000000549.
  3. Wilkoff BL, Fauchier L, Stiles MK, et al. 2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing. Heart Rhythm. 2016;13(2):e50-e86. doi:10.1016/j.hrthm.2015.11.018.
  4. Indik JH, Gimbel JR, Abe H, et al. 2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices. Heart Rhythm. 2017;14(7):e97-e153. doi:10.1016/j.hrthm.2017.04.025.
  5. Kusumoto FM, Schoenfeld MH, Wilkoff BL, et al. 2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction. Heart Rhythm. 2017;14(12):e503-e551. doi:10.1016/j.hrthm.2017.09.001.
  6. American Heart Association. Implantable Cardioverter Defibrillator (ICD). American Heart Association.
  7. American Heart Association. Living With Your Implantable Cardioverter Defibrillator (ICD). American Heart Association.
  8. American Heart Association. Devices That May Interfere With ICDs and Pacemakers. American Heart Association.
  9. U.S. Food and Drug Administration. Magnets in Cell Phones and Smart Watches May Affect Pacemakers and Other Implanted Medical Devices. FDA.
  10. British Heart Foundation. Implantable cardioverter defibrillators (ICDs). British Heart Foundation.
  11. Leeds Teaching Hospitals NHS Trust. Your guide to living with your implantable cardioverter defibrillator. Reviewed 10 March 2026.

Informational notice: the information contained on this page is provided solely for informational and educational purposes and does not replace the advice, diagnosis or treatment provided by a physician. If needed, always consult a qualified healthcare professional.

Artificial intelligence transparency: this page was created with the support of artificial intelligence tools, used to assist in the production and processing of its content.