When an abdominal aortic aneurysm requires repair, the two principal approaches are EVAR, meaning endovascular repair using a stent graft, and open surgery. Neither technique is universally superior: the choice depends on aneurysm anatomy, biological age, general health, life expectancy, operative risk, and the ability to undergo long-term follow-up.
EVAR is less invasive and generally offers faster recovery and lower perioperative risk. Open surgery involves a more major procedure but is highly durable and reduces the likelihood of future corrective procedures for problems specific to a stent graft.
In summary:
The decision should be made with a vascular surgeon following CT angiography for procedural planning and an assessment of operative risk. European guidelines explicitly recommend shared decision-making that also takes account of the patient's preferences and ability to adhere to follow-up.
EVAR stands for Endovascular Aneurysm Repair. The stent graft is introduced through one or both femoral arteries, usually via access sites in the groin, and positioned inside the aorta under fluoroscopic guidance. Once deployed, it creates a new channel for blood flow and reduces pressure on the aneurysm sac.
The principle is therefore not to 'remove' the aneurysm: the sac remains in place but is excluded from the effective circulation.
For EVAR to work, sufficient healthy aortic segments must be present above and below the aneurysm for the stent graft to seal against. Important factors include the length and shape of the aortic neck, angulation, diameters, calcification, thrombus, iliac artery dimensions, and vascular access routes.
For aneurysms close to the renal or visceral arteries, fenestrated or branched devices may be required to maintain blood supply to the organs. These procedures are more complex than standard EVAR and must be assessed at experienced centres.
The main advantage of EVAR is less operative trauma. The procedure can be performed through percutaneous access or small groin incisions, often without a laparotomy, and recovery is generally shorter. In randomised trials, EVAR has shown a perioperative mortality advantage over open surgery.
This initial advantage tends to diminish over the long term, partly because complications related to the device or progressive aortic changes may develop after EVAR.
In open surgery, the surgeon accesses the aorta through the abdomen, temporarily controls blood flow with a clamp, and functionally replaces the aneurysmal segment with a synthetic graft sutured to the aorta. The aneurysm wall is then generally closed around the graft.
This is major surgery requiring general anaesthesia, placing greater cardiovascular and respiratory demands on the patient and involving a longer recovery than EVAR.
Its principal strength is durability. A well-implanted surgical graft does not depend on endovascular landing zones in the same way as a stent graft and is not subject to endoleaks. Late complications do occur, including anastomotic problems, abdominal wall hernias, and graft infection, but they are relatively uncommon.
Open surgery therefore remains particularly relevant for younger patients, those in good general health, people with long life expectancy, or patients whose anatomy is poorly suited to EVAR.
The 2024 ESVS guidelines state that open surgery should be considered the preferred approach in patients with long life expectancy, while the 2024 ESC guidelines emphasise that EVAR should be considered in patients with favourable anatomy and reasonable life expectancy, within a shared decision-making process. This is not a practical contradiction: it means that the expected durability of the repair carries greater weight the longer the anticipated lifespan.
The first consideration is anatomy. If the stent graft cannot achieve a reliable seal or access vessels are inadequate, standard EVAR is not a good option. Implanting a stent graft outside the device's anatomical instructions for use increases the risks of endoleak, migration, loss of seal, and reintervention.
At specialised centres, some complex anatomical configurations can be treated with fenestrated or branched stent grafts, but this does not mean that every aneurysm is automatically suitable for endovascular repair.
The second factor is operative risk. A person with severe respiratory or cardiac disease, or other comorbidities, may tolerate laparotomy and aortic clamping poorly. In these patients, if the anatomy is suitable, EVAR may offer a substantial advantage.
Conversely, a younger, healthy person with decades of expected survival may place greater value on the durability of open repair and the lower likelihood of reinterventions specific to stent grafts.
Renal function, previous abdominal surgery, the presence of stomas or a hostile abdomen, obesity, the quality of femoral access, iliac artery characteristics, and personal preferences also matter. The ability to return for surveillance is essential: EVAR requires ongoing follow-up and is not ideal if this cannot be ensured.
In very frail patients or those with a life expectancy of less than approximately two years, European guidelines generally advise against elective AAA repair because the risks and burden of treatment may outweigh the expected benefit.
After EVAR, hospitalisation is generally shorter and mobilisation faster. Postoperative pain is often less severe, and the absence of a large abdominal incision facilitates recovery. Following open surgery, more time is needed for bowel function to return, abdominal wall healing, and recovery of overall strength.
The initial advantage of EVAR must, however, be balanced against the need to monitor the stent graft.
The best-known specific complication is endoleak, meaning persistent blood flow within the aneurysm sac outside the stent graft. Some types require correction; others may be monitored if the sac is not enlarging. Migration, loss of seal, limb occlusion, or structural device problems can also occur.
This is why early imaging is performed after EVAR, generally at approximately one month, followed by risk-adjusted surveillance. CT, Doppler ultrasonography, and contrast-enhanced ultrasound can be combined to reduce radiation exposure and contrast medium use in suitable patients.
After open surgery, follow-up may be much less frequent if the repair is stable. Nevertheless, late complications such as para-anastomotic aneurysms or new dilatation in other vascular segments remain possible.
Regardless of technique, stopping smoking, controlling blood pressure, lipids, and diabetes, and maintaining appropriate cardiovascular follow-up remain essential elements of care.
Is EVAR a stent?
In everyday language it is often called a 'stent', but technically it is a covered endovascular prosthesis, or stent graft, which creates a new channel within the aorta and excludes the aneurysm sac.
If I am eligible for EVAR, should I always choose it?
No. Anatomical suitability is only one consideration. Biological age, life expectancy, operative risk, the expected durability of the repair, and ability to attend follow-up all affect the choice.
Does the aneurysm disappear after EVAR?
No. The aneurysm sac remains but is excluded from the main blood flow. Follow-up checks whether it is still under pressure and whether it tends to remain stable or shrink.
Are follow-up checks unnecessary after open surgery?
Follow-up is still necessary, although it is often less frequent than after EVAR. The graft and other segments of the aorta must be reassessed over time.
Which technique is better for a healthy 60-year-old?
The decision cannot be made on age alone. In a relatively young and fit person, the durability of open repair carries greater weight, but anatomy, comorbidities, and preferences may still make EVAR an appropriate choice. An individual assessment is required.